Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
Search Results "Exterior Exit Stairway"
-
210.1 General
- Besam SL500 CGL Commercial Glass Entry Door - Fixed Sidelite SS BIM
-
D. Protruding Objects
Protruding Objects - Examine all interior hallways, stairways and other pedestrian routes: ...to minimize the risks to blind persons and persons with low vision, are all of these areas...
- Allen Tel ADA Outdoor Phones for Hearing Impaired Single Number Dial
- Heavy Duty Telephone Manual Dialing with Keypad
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. Swinging doors shall provide a net clear opening width of not less...
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
Telephones: ADA Standard Section 217
Section 217 covers scoping requirements in the current ADA Standards for telephones.
-
General: ADA Standard Section 217.1
Section 217.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for telephones.
-
11B-217 Telephones
[See subsections ...]
-
11B-217.1 General
Where coin-operated public pay telephones, coinless public pay telephones, public closed-circuit telephones, public courtesy phones, or other types of public telephones are provided,...
-
11B-217.1 General
Where coin-operated public pay telephones, coinless public pay telephones, public closed-circuit telephones, public courtesy phones, or other types of public telephones are provided,...
-
11B-217 Telephones
[See subsections ...]
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5....
-
1007.2, Item 10
Exterior area for assisted rescue complying with Section 1007.7....
-
1007.8.3 Identification
Exterior areas for assisted rescue shall have identification as required for area of refuge that complies with Section 1007.6.5....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
1015.3 Height
On stairways and stepped aisles, from the line connecting the leading edges of the tread nosings. On ramps and ramped aisles, from the ramp surface at the guard....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
Examples include exit-only doors with no operating hardware on the exterior side or separate enter and exit fare gates in transit stations....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior...