Elevators Common Problem: Lodging facilities with more than two floors of occupiable space - including any basement levels - do not have full-size passenger elevators available for...
Search Results "Elevator Hall Signal"
Commonly Searched Documents
-
Elevators
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
- Savaria ORION Limited Use/Limited Application Elevator Video
-
Issue 4: Wrong pole! …Wrong message!
However, APS can be wired to a control board in the pedestrian signal head or through the controller, so it may be necessary to move the pedestrian signal head (or to completely rewire each...
-
407.4.8.2.1 Signal Type
407.4.8.2.1 Signal Type. The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Issue 7: Repair/replacement (put it back right!)
Issue 7: Repair/replacement (put it back right!) An APS that was knocked down in a crash was reinstalled by workers who did not know how the device was supposed to function. After...
-
Pushbutton locator tone
Pushbutton locator tone The pushbutton locator tone is a low-volume tick or tone that repeats constantly, at one-second intervals, during the flashing and steady DON’T WALK...
-
11B-407.4.7 Designations and indicators of car controls
Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 is provided, existing car operating panels may remain operational and shall not be required...
-
Issue 11: Good vibrations (vibrotactile indications)
The vibrotactile indication provides WALK signal information for pedestrians who are both visually and hearing impaired and also may be used by pedestrians who are visually impaired (with...
- Schumacher Elevator Company: Virtual Plant Tour in HD by SAPTV
-
Tactile arrow
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
-
Elevators: ADA Standard Section 216.7
Section 216.7 covers scoping requirements in the current ADA Standards for signs at elevators.
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Private Residence Elevators: ADA Standard Section 409
Section 409 covers the current ADA Standards for private residence elevators.
-
407 Elevators
Section 407 covers passenger elevators, including destination-oriented elevators and existing elevators....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3.
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button. The accessibility function button shall be located...
-
Keypads: ADA Standard Section 407.4.6.3
Section 407.4.6.3 covers the current ADA Standards for elevator car control keypads.
-
Passenger Elevators
Section 206.6 requires each passenger elevator to comply with the requirements for standard elevators or destination-oriented elevators....
-
Elevated: ADA Standard Section 1008.2.5.2
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-233.3.1.2.1 Elevator buildings
A residential building with one or more elevators shall have an elevator serve all floors with a residential dwelling unit primary entrance and all floors with common use areas....