All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
Search Results "Elevator Hall Call Button"
Commonly Searched Documents
-
4.10.12(3)
-
4.10.12(3)
All floor buttons shall be no higher than 48 in (1220 mm), unless there is a substantial increase in cost, in which case the maximum mounting height may be increased to 54 in (1370 mm),...
-
Visible Indicators: ADA Standard Section 407.4.7.1.4
Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons.
-
4.10.12(2)
The call button for the main entry floor shall be designated by a raised star at the left of the floor designation (see Fig. 23(a))....
-
Elevators: ADA Standard Section 407
Section 407 covers the current ADA Standards for elevators.
-
Preserving elevator access in building where it might not be required.
Each story less than 3000 square feet, so elevator would likely not be required if built new. 2010 Standards 206.2.3, Exception 1. ...
-
11B-411.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-411.4.6 and 11B-309.4....
-
Operation: ADA Standard Section 407.3.2
Section 407.3.2 covers the current ADA Standards for elevator door operations.
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
-
Designations and Indicators of Car Controls: ADA Standard Section 407.4.7
Section 407.4.7 covers the current ADA Standards for designations and indicators of elevator car controls.
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
e-v
Are raised letters and Braille characters used to identify each floor button and each control? [ADA Standards § 4.10.12] Yes No...
-
11B-407.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-407.2....
- Schumacher 1400 Series Limited Use Limited Application (LULA) Elevator
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
11B-407 Elevators
[See subsections ...]
-
Alterations to elevators. (Section-by-Section Analysis)
call button as the altered elevator....
-
11B-408.4 Elevator cars
Elevator cars shall comply with Section 11B-408.4....
-
Alterations to Existing Elevators
button as the altered elevator....
-
Elevators
If elevators are altered, all cars programmed to respond to the same call control must be similarly modified (§206.6.1)....
-
Car Controls [§407.4.6 and §407.4.7]
Car Controls [§407.4.6 and §407.4.7] If more than one car control panel is provided in a car, both must comply (except in existing cars where only 1 panel must comply). Car...
-
Keypad Buttons
The proposed rule, in addressing elevator car controls, required that telephone-style keypad buttons, where provided, be identified by raised characters centered on the keypad button (407.2.11.2...
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....