If a particular entrance is not made accessible, appropriate accessible signage indicating the location of the nearest accessible entrance(s) shall be installed at or near the inaccessible...
Search Results "EVCS Signage"
Commonly Searched Documents
-
4.1.6(1)(h) Entrances
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. Stroke...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous. It also...
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
11B-703.5.7 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
Circulation and flow
There is no signage to the interior accessible route between the Museum lobby and the Spy City Café. See Standards § 4.1.2(7)(c). b....
-
There is some confusion about whether the “accessible path” that is required means there must be an accessible path from the EVSE (charger) to the facility/building at which the station is installed, or whether the accessible path is just from the parking spot to the EVSE (charger). If the prior is enforced, it could increase the costs of installing EVSE in some instances. What is the correct interpretation of “accessible path”?
EVCS required by CBC Chapter 11B to be accessible must have both, an accessible route to the facility entrance (see CBC Section 11B-812.5.1) and an accessible route from the vehicle space...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
Can you upgrade/expand an existing location without adhering to ADA standards?
To the extent that EVCS are a public accommodation or commercial facility they are covered by the federal law of the Americans with Disabilities Act....
-
11B-502.6 Identification
Parking space identification signs shall include the International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background. Signs identifying van...
-
11B-216.5.2 Parking facilities
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the...
-
4.1.3(16)(b)
(b) Other signs which provide direction to or information about functional spaces of the building shall comply with 4.30.1, 4.30.2, 4.30.3, and 4.30.5. EXCEPTION: Building...
-
11B-216.5.2 Parking facilities
Signs within parking facilities shall comply with Section 11B-216.5.2.