Doors, Doorways and Gates [§206.5 and §404] Compliance is required for doors, doorways, and gates providing user passage on accessible routes....
Search Results "Door Height"
Commonly Searched Documents
-
Doors, Doorways and Gates [§206.5 and §404]
-
4.16.3* Height
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
4.16.3* HEIGHT
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 2
- Pressalit Care Adult changing table 3000, electrically height adjustable 3D CAD Model
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 1
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates The SNPRM would revise R218 to read as follows: R218 Doors, Doorways, and Gates....
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
Counter Surface Height
Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
-
Toilet Room Doors
Sections 4.22.2 and 4.22.3 of the 1991 Standards and Section 603.2.3 of the 2010 Standards permit the doors of all toilet or bathing rooms with in-swinging doors to swing into the required...
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
404.2.4.3 Recessed Doors and Gates
404.2.4.3 Recessed Doors and Gates....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....