- DSA Drawing 11B-406-10C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
-
DSA Drawing 11B-406-2 Perpendicular Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
2. Age of Streets and Sidewalks
In addition, the requirements vary depending on the age of a highway, road, street, or sidewalk, and depending on when and whether it was paved, repaved, resurfaced beyond normal...
-
R304.5.5 Clear Space
R304.5.5 Clear Space. Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street...
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
Ramps [4.8]
Generally, changes in level up to 6 inches can be treated as a curb ramp....
-
B7
If there is a curb between the access aisle and the accessible route to the building, is there a curb ramp that meets the following requirements: [ADA Standards § 4.7]    Yes    No...
-
DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
4.7.2 SLOPE
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
4.7.2 Slope
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
11B-810.2.3 Connection
constructed bus stop boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb...
-
Appendix 1: ADA Accessibility Survey Instructions: Curb Ramps
[See subsections ...]
-
A8
Does an accessible route connect the curb ramp to the shelter’s accessible entrance? [ADA Standards § 4.1.2(1)]    Yes    No...
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
- Collapsible Water Retainer Shower Dam for Shower Threshold Information Video
-
R207.1 General
A curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with R304 shall connect the pedestrian access routes at each pedestrian street crossing....
-
DSA Drawing 11B-406-6C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Governmental Units Affected (R208 Detectable Warning Surfaces) (Section-by-Section Analysis)
The Access Board seeks information on whether any state and local transportation departments currently use UFAS for curb ramps in the public right-of-way....