The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
Search Results "Clear Tread Width"
Commonly Searched Documents
-
1009.3.3 Handrails
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Accessible Route
accessible route but where they are required to comply with 4.9, it is recommended that routes to them meet the requirements for accessible routes since certain specifications, such as clear...
-
11B-224.1.2 Guest room doors and doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
§ 38.113(a)(1)
accessible by §38.111(a) and where the spaces required by §38.111(d) of this part are located, and at least one adjacent doorway into coach passenger compartments shall have a minimum clear...
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
-
§ 38.113(a)(2)
connecting two adjacent cars, to the maximum extent practicable in accordance with regulations issued under the Federal Railroad Safety Act of 1970 (49 CFR parts 229 and 231), shall have a clear...
-
Handrails
The clear width between handrails must be between 33 and 38 inches. The handrail height must be between 34 and 38 inches to the top of the gripping surface....
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
Road Closure Drawings
Many forest roads are closed to motor vehicle traffic by gates or other types of barriers. Often, foot travel is allowed beyond the restriction device. When foot travel is encouraged...
-
8.5 Stacks
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
8.5 STACKS
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
Stairways [§504]
Stairways [§504] Requirements for stairways address treads and risers, surfaces, nosings, and handrails....
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water. ...