f-vii. Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No
Search Results "Camp Shelter"
Commonly Searched Documents
-
f-vii
-
J3
J3. Is the top of the spout no higher than 36 inches above the floor and at the front of the fountain or water cooler? [ADA Standards § 4.15.2] Yes No
-
H23
H23. Is the door to the toilet stall located diagonally opposite, not directly in front of, the toilet or on the opposite side wall from the wall with the long grab bar? [ADA...
-
J4
J4. Does the water rise at least 4 inches high when no more than 5 pounds of force is applied to the controls of the fountain? [ADA Standards §§ 4.15.3 and 4.15.4] Yes No
-
f-iv
f-iv. Does the ramp have a level landing at the top and bottom of each ramp section that is at least 60 inches long? [ADA Standards § 4.8.4] Yes No Note: The level...
-
1011.1 General
The requirements in 1011 apply to outdoor constructed features provided within camping facilities, picnic facilities, viewing areas, and trailheads or on trails....
-
F202.4 Alterations Affecting Primary Function Areas
Camping facilities, picnic facilities, viewing areas, trailheads, trails, and beach access routes shall not be required to comply with F202.4....
-
§301(7)(K)
A day care center, senior citizen center, homeless shelter, food bank, adoption agency, or other social service center establishment; and...
-
F244.5.2.1 Routes to Common Use and Public Use Areas
At least one outdoor recreation access route shall connect each camping unit with mobility features with common use and public use areas serving the unit....
-
F244.5.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving camping units with mobility...
-
9.5 Transient Lodging in Homeless Shelters, Halfway Houses, Transient Group Homes, and Other Social Service Establishments
[See subsections ...]
-
F202.3 Alterations
Where elements or spaces are altered in camping facilities, picnic facilities, viewing areas, or trailheads and the circulation path to the altered element or space is not altered, the circulation...
-
F213.1 General
EXCEPTION: Pit toilets provided on trails and in camping facilities shall not be required to comply with F213. Advisory F213.1 General. ...
-
F247.4.4 Routes
Routes that connect trails complying with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities shall comply with...
-
F212.3 Sinks
In camping facilities and picnic facilities, sinks shall not be required to comply with F212.3 where a cooktop or conventional range is not provided....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete, or...
-
1012.3 Other Vehicles
This section requires parking spaces for vehicles, other than recreational vehicles, to be 16 feet wide minimum to accommodate vans equipped with a lift or ramp. Where two adjacent...
- Simple Pump Company ADA 100 Simple Water Pump
-
K3
Tables can be relocated as needed during operation of the shelter....
-
Section 9, Accessible Transient Lodging (Preamble, Section-by-Section Analysis)
In new construction, homeless shelters and other social service entities must comply with ADAAG; at least one type of amenity in each common area must be accessible....
-
f-vi
f-vi. Are the controls and operating mechanisms usable with one hand without tight grasping, pinching, or twisting? [ADA Standards §§ 4.11.2, 4.27.4] Yes No
-
H25
H25. Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees? [ADA Standards §...
-
L1
L1. Is there a backup source of electrical power for the facility? Yes No
-
H9
H9. Are the drain and hot water pipes for this lavatory insulated or otherwise configured to protect against contact? [ADA Standards § 4.19.4] Yes No