CHAPTER 4: BOARDING AND ALIGHTING
-
Height
Height Where railings, guards, or handrails are provided on a fishing pier or platform, at least 25 percent of the rails must be 34 inches or less in height above the ground or deck...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface. Exception: Where a guard complying with Chapter 10,...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface. Exception: Where a guard complying with Chapter 10,...
- Floating Trail Bridges and Docks
-
Two Step Transfers Attainable Heights
Among the participants that were able to complete the two step transfers, the 5th percentile were able to transfer to a second platform that was 3 inches higher than the first...
-
R308.1.3 Common Requirements
Boarding and alighting areas and boarding platforms shall comply with R308.1.3....
-
Research Projects
The Board sponsors and coordinates research for use in developing accessibility guidelines and providing technical assistance to the public....
-
§382.65 What are the requirements concerning on-board wheelchairs?
[See subsections ...]
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
T502.3.2 Thresholds
Thresholds at doorways shall be marked by a stripe. The stripe shall be 1 inch (25 mm) wide minimum and contrast with the rest of the walking surface either light-on-dark or...
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2. ...
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2....
-
11B-247.2 Detectable directional texture
At transit boarding platforms, the pedestrian access shall be identified with a detectable directional texture complying with Section 11B-705.2....
-
§ 38.91(c)(1)
(1) Commuter rail cars shall comply with §§38.93(d) and 38.109 of this part for level boarding unless structurally or operationally impracticable....
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform....
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
1:6 maximum (17 percent) – for ramps deployed to roadways or to boarding and alighting areas without boarding platforms (i.e., curb-height bus stops)....