For those reasons, the opening provided to transfer from a wheelchair or mobility device must provide sufficient clearance for transfer....
Search Results "Door Opening Angle"
Commonly Searched Documents
-
Transfer Entry
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
11B-307.2 Protrusion limits
Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). ◼ ...
-
611.3 Operable Parts
Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with 309....
-
LaCantina Doors Slider Contemporary Clad, Pocket, Flush Sill - Meeting in the Middle
Requires the Premium User plan or above. (Login or upgrade your account!)
- Quantum Single Load Dryer Front Control by Speed Queen
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
Maintenance of Accessible Features
Inoperable elevators, locked accessible doors, routes that are obstructed by furniture are neither "accessible to" nor "usable by" people with disabilities....
-
1007.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
Personal Support:
This is important so you have at least one back-up if your primary person forgets, or is not available. 1.2 * Don’t use the door night latch or dead bolt lock button on your door if you...
- Sears Brands, LLC Craftsman Digital Torpedo Level
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
Problem Three (Protruding Objects)
Problem Three: The bottom of a set of stairs is open and voters who are blind or have vision loss can hit their head on the underside of the stairs....
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
Room Dimensions
single-user toilet rooms, key considerations include the configuration of water closets and lavatories, clear floor spaces required at fixtures, turning space, the location and swing of doors...
-
1011.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”...
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
4. Comparison of Proposed Technical Provisions Applicable to Shared Use Paths and AASHTO Guide
R302.7.3 Horizontal Openings. Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm (0.5 in) in diameter....
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. [ECTCR UFAS 4.20.7]...
-
§27.71(k)(5)(iii) Captioning.
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 27.71(k)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....