three essential features are one entrance with zero steps; 32 inches or more of clear passage space through interior doors, including bathrooms; and at least a half bathroom on the main floor...
Search Results "Ground Floor"
- Visitability
-
Car Position Indicators [4.10.13]
Verbal announcements must announce each floor a car stops at but not each floor passed....
-
Seat Heights
Seat Heights: Transfer platforms in play areas need to be between 11 and 18 inches maximum above the ground (ADA-ABA Section 1008.3.1.2)[7]....
-
Protrusions
Where a wheelchair space is located on a ride, nothing may protrude into the front of the wheelchair space 9 inches from the floor....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the...
-
Do all state and local buildings need to be accessible (comply with the ADA Standards for Accessible Design?)
In a two story town hall built in 1968 that doesn’t have an elevator, staff on the second floor could meet with citizens on the first floor if meeting space is comparable to that on the...
-
M303.2.4.2 Knee Clearance
Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm) minimum...
-
Use Zone
The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see "Referenced Standards" in Chapter...
-
106.5.74 Use Zone
The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see "Referenced Standards" in Chapter...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
Drinking Fountain Scoping for Exterior Sites
In the final rule, scoping has been clarified as applying to units provided at "exterior sites," in addition to those installed on floors....
-
Example: Historic House Museum
The town develops plans to alter the facility to provide physical access to the first floor....
-
Free-Standing Overhead Lifts
Free-Standing Overhead Lifts Another type of overhead lift is supported from a frame that rests on the floor....
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
- AJW Architectural Products US19 Collapsable Security Hook, Exposed Mounting - Surface Mounted
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....