The U.S. standards are in more need of change but the basis for many of the changes previously made to the standards in Canada, the U.K. and Australia can also be questioned in light of...
Search Results "Applicable Standard"
-
5.0 Conclusions
-
National Council on Independent Living
The surface height we had recommended historically was 17 to 19 inches above the floor, which has been around for years in existing Standards....
-
202.3.1 Prohibited Reduction in Access
Justice regulations 28 CFR 35.133 for public entities (Title II) and 28 CFR 36.211 for private entities (Title III) clarify that reduction of accessibility is benchmarked to the 2010 ADA Standards...
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
See Standards § 4.13.11(2)(b). gg. The women's toilet room stall door hardware requires tight grasping and twisting of the wrist. See Standards § 4.13.9. hh....
-
22. Q. We are building a new prison. Do we need to make it accessible?
The ADA provides architectural standards that specify what must be done to create access....
-
Required Compliance [§210]
Required Compliance [§210] Interior and exterior stairs that are part of a required means of egress must meet the Standards....
-
SUMMARY:
HUD is issuing this document to permit recipients of Federal financial assistance from HUD (HUD recipients) to use an alternative accessibility standard for purposes of complying with Section...
-
11B-202.3 Alterations
Where existing elements or spaces are altered, each altered element or space shall comply with the applicable requirements of Division 2, including Section 11B-202.4 _|Alterations; Path...
-
11B-604.5.2 Rear wall
ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, issued Code Application...
-
11B-604.5.2 Rear wall
ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, issued Code Application...
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-407.4.6.2.1 Size and shape
[2010 ADA Standards] 407.4.6.2.1 Size. Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
PRIVATE BUILDING OR FACILITY
[2010 ADA Standards 106.5] Private Building or Facility....
-
11B-407.2.2.1 Visible and audible signals
[2010 ADA Standards] 2. In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.2.2.1 Visible and audible signals
[2010 ADA Standards] 2. In existing elevators, a signal indicating the direction of car travel shall not be required....
-
PRIVATE BUILDING OR FACILITY
[2010 ADA Standards 106.5] Private Building or Facility....
-
11B-407.4.6.2.1 Size and shape
[2010 ADA Standards] 407.4.6.2.1 Size. Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
§382.133(f)(2)
(2) Any applicable requirement for a manufacturer-affixed label to reflect that the device has been tested to meet requirements for medical portable electronic devices set by the FAA for...
-
Sources
In addition to applicable provisions of Part 382, the sources for this guidance include the following: “Guidance Concerning Service Animals in Air Transportation,” (61 FR 56420-56422, (November...
-
1.9.1.2
1.9.1.2 Application. See Health and Safety Code commencing with Section 19952....
-
382.141 What training are carriers required to provide for their personnel?
There are a few differences, in view of the rule’s application to foreign carriers....
-
Other Accessible Elements
Other Accessible Elements If swimming pools are part of a multi-use facility, designers and operators must also comply with ADAAG and all applicable requirements for recreation facilities...
-
R202.3 Alterations
Where existing elements, spaces, or facilities are altered, each altered element, space, or facility within the scope of the project shall comply with the applicable requirements for new...