(i) In alterations where it is structurally impracticable to disperse seating throughout the assembly area, seating may be located in collected areas as structurally feasible....
Search Results "Securement Location"
-
4.1.6(4)(f)
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
III-5.4300 Transportation terminals
all passenger services in a two-story facility - including boarding, debarking, loading and unloading, baggage claim, dining facilities, and other common areas open to the public - are located...
-
Press Boxes [§206.2.7]
all press boxes serving a playing field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade at least 12’ or located...
-
C. JURISDICTION AND VENUE
. § 1391 because the County is located in this District and all of the claims and events giving rise to this action occurred in this District....
-
1009.6.4 Separation
Exceptions: Areas of refuge located within an enclosure for interior exit stairways complying with Section 1023....
-
§ 38.125(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a seating location...
-
§ 38.173(a)
., at a speed of no more than 20 miles per hour at any location on their route during normal operation), shall comply with the provisions of §38.53 (a) through (c), and §§38.55 through 38.61...
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.9.1 Clear floor space
floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following locations...
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
- Trimco LDH100 Series Lockdown Hardware
- EZ-ACCESS Transitions® Modular Entry Mat
-
Section 35.151(g)(2)
In the NPRM, the Department proposed Sec. 35.151(g)(2) which prohibits wheelchair spaces and companion seating locations from being “located on, (or obstructed by) temporary platforms or...
-
Contrast
The proposed rule specified that detectable warnings in interior locations differ from adjoining walking surfaces in resiliency or sound-on-cane contact (705.2.3)....
-
Two-Way Communication
Comments recommended that the guidelines address emergency communication systems located in a closed compartment and apply the specifications for operable parts in section 309 to compartment...
-
Benches
If the bench is not located next to a wall, the bench must have back support that is 42 inches minimum in length and extends from a point 2 inches maximum above the seat to a point 18 inches...
-
F240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
Data Analysis
For example, the area measurement depends on two variables that cannot be analyzed separately: the amount of space occupied by the physical dimensions of the WMD user and the actual location...
-
F) Library Services
may have a facility that is difficult to make accessible or lack the resources to make essential physical changes may choose to offer the programs and services in an alternate accessible location...
-
240.1.1 Additions
When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types,...
-
5.1 Public Notification of Availability
This notification should be of the same order of visibility and location as information regarding other attributes of a performance ("Dolby Sound", etc.)....