Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below....
Search Results "Elevator Building"
-
106.5.38 Mezzanine
-
11B-902.2.1 Overlap
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Section 11B-902.2 has been amended...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
FACILITY
All or any portion of a building, structure, or area, including the site on which such building, structure or area is located, wherein specific services are provided or activities performed...
- Harmar RPL Residential Vertical Platform Lift
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5)....
-
4.1.3(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
4.1.3(8)(b)(i)
(i) In addition, if direct access is provided for pedestrians from an enclosed parking garage to the building, at least one direct entrance from the garage to the building must be accessible...
-
4.1.2(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
206.4.2 Parking Structure Entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with 404...
-
101.1.2
101.1.2 All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation, and commercial facilities subject to this code shall comply...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
4.4.5 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
5.1.8 Slope
Exception: When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces....
-
Mezzanine
Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below....
-
§104.23(c)(1)
(1) Effective as of January 18, 1991, design, construction, or alteration of buildings in conformance with sections 3-8 of the Uniform Federal Accessibility Standards (UFAS) (Appendix A...
-
4.6.2 Location
Accessible parking spaces serving a particular building shall be located on the shortest accessible route of travel from adjacent parking to an accessible entrance....
-
4.1.4(13) UTILITY AND MISCELLANEOUS
Utility and miscellaneous occupancies include, among others, accessory buildings and structures, such as: Facilities Fences over 6 ft. high Tanks Cooling towers Retaining...
-
F202.2.4 Public Telephone
Where a public telephone is not provided in an addition but is provided in the existing building or facility to serve the addition, at least one public telephone in the existing building...
-
Section 2. Public use areas
"Public use areas" means interior or exterior rooms or spaces of a building that are made available to the general public....