Minimum clear aisle space at card catalogs, magazine displays, or reference stacks shall comply with Fig. 55....
Search Results "Water Closet Clear Floor Space"
-
8.4 CARD CATALOGS
-
D. Suites:
PSE shall provide accessible coat closets, including appropriate shelving and hooks, in all Palace suites. See the 2010 Standards §§ 225.2, 305, 308, 309 and 811....
-
Clearance
Wider clearances are specified for wheelchair passing space (60 inches minimum) and certain sharp turns around narrow obstructions....
-
11B-812.8.7 Location
Signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected vehicle space width at the head end of the vehicle space....
-
11B-812.8.7 Location
Signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected vehicle space width at the head end of the vehicle space....
- Space Coast Center for Independent Living, Inc. (SCCIL) - Rockledge, FL
-
Trash, Recycling, and Other Essential Containers
The clear space may overlap the clear space for adjacent containers. It must be adjacent to and may overlap the outdoor recreation access route....
-
11B-411.4.6.2 Buttons
The car shall not have non-functional, exposed floor buttons....
-
11B-411.4.6.2 Buttons
The car shall not have non-functional, exposed floor buttons....
-
F206.7.4 Judicial Spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges' benches, clerks' stations, bailiffs'...
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
TABLE OF CONTENTS
or Ground Surfaces 303 Changes in Level 304 Turning Space 305 Clear Floor or Ground Space 306 Knee and Toe Clearance 307 Protruding Objects 308 Reach Ranges 309 Operable...
-
Visible Indicators: ADA Standard Section 407.4.7.1.4
Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons.
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
General: ADA Standard Section 609.1
Section 609.1 of the ADA Standards covers information in the current ADA Standards for grab bars in toilet facilities and bathing facilities.
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project more...
-
4.33.4 Surfaces
The ground or floor at wheelchair locations shall be level and shall comply with 4.5....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
Calculation of Percentages
Some provisions in the ADA Standards specify a minimum number of elements or spaces as a minimum percentage or proportion....
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
4.5.1* General
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall...
-
806.2.4 Toilet and Bathing Facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610....