In the approximately seventeen years since the Supreme Court’s decision in Olmstead v. L.C. ex rel....
Search Results "Court Floor Holding Cell"
-
Statement of the Department of Justice on Application of the Integration Mandate of Title II of the Americans with Disabilities Act and Olmstead v. L.C. to State and Local Governments' Employment Service Systems for Individuals with Disabilities
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
1134A.7 Water closets
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
- Guldmann Basic High Bariatric Sling, 1100 lbs / 500 kg
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.34.6.4(4)
(4) A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall allow a forward approach to the counter....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- TOTO® CT705ELN Commercial Flushometer High Efficiency Toilet
- American Specialties Omara Collection Spare Toilet Paper Roll Holder 7316
- Brooks Equipment FIRETECH™ Fire Extinguisher Stand
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
Bedside Clearance [9.2.2(1)]
Clear floor space is required at accessible controls and elements (e.g., thermostats), storage facilities (e.g., closets), and should be provided at non-fixed furnishings (e.g., dressers...
-
Application
Application A child welfare agency or court may not, directly or through contract or other arrangements, engage in practices or methods of administration that have the effect of discriminating...
- BEA Inc. LZR Microscan Installation Video
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
§ 38.95(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
§ 38.125(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Waviness Index
Waviness Index The Waviness Index, ASTM E 1486, Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria, was developed in response to the...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
