If self-service fare collection devices are provided for the use of the general public, at least one accessible device for entering, and at least one for exiting, unless one device serves...
Search Results "Exit Door"
-
220 Automatic Teller Machines and Fare Machines
-
Taking Measurements
To measure the opening of a standard hinged door, open the door to 90 degrees....
-
Height: ADA Standard Section 611.4
Section 611.4 covers the current ADA Standards for the height of the laundry compartment in top loading machines and front loading machines.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- Viking Tactile Blue Braille and Raised Letter Sign
- Schindler's Elevator PORT (Personal Occupant Requirement Terminal)
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
Door King Inc. 1837 PC Programmable IM Server Overview
Requires the Registered User plan or above. Login!
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibules if provided, the entry door(s) or gate(s), and the...
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing wheelchair spaces with one entry that also serves as the exit, the length of the gripping surface of horizontal standing supports shall be equal to or...
-
Surprise Drills
., blocked paths or exits), forcing people to use alternative routes. Performance of these drills should also be evaluated and feedback given to all participants. ...
-
Elevators with Standby Power [IBC §1007.4 (2003), §1003.2.13.3 (2000)]
In buildings with four or more stories above or below the level of exit discharge, at least one accessible means of egress must be an elevator with standby power and emergency signaling...
-
Threshold Height
Conversely, a few comments urged that this exception be broadened to restore a similar allowance for exterior sliding doors. Response....
-
Limited-Use/ Limited-Application Elevators [§408]
However, LULAs have smaller car sizes, slower speeds, shorter travel distances, and alternative types of doors....
-
1134A.5, Item 5
Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
1134A.6, Item 7
Doors and panels of shower enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged shower doors shall open outward....
-
1134A.5, Item 5
Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
1134A.6, Item 7
Doors and panels of shower enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged shower doors shall open outward....
-
Emergency Planning
detail procedures for providing evacuation assistance to people who would have difficulty or who would be unable to: Use stairwells, Hear alarms, See exits...
-
11B-240.2.2 Elevated play components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....