facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall...
Search Results "Control End Wall"
-
11B-201.3 Temporary and permanent structures
-
11B-809.9.3 Removable base cabinets
following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor extends under the base cabinet; and c) the walls...
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
229 Windows
requirement at section 229.1 of the 2010 Standards provides that if operable windows are provided for building users, then at least one window in an accessible space must be equipped with controls...
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
11B-608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls...
-
11B-608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls...
-
407.12 Reach Height (Section-by-Section Analysis)
This flexibility would allow manufacturers to assess conformance prior to sale and independent of factors outside their control....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction...
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational. Requiring passengers to manually activate such signals...
-
§382.101(e)
(e) Circumstances beyond your control (e.g., unusually severe weather; unexpected mechanical problems) prevent the use of a lift....
-
606.4 Faucets
Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
§ 1194.23(k)(4)
(4) The status of all locking or toggle controls or keys shall be visually discernible, and discernible either through touch or sound....
-
§ 1194.25(j)(4)
(4) Operable controls shall not be more than 24 inches behind the reference plane (see Figure 2 of this part)....
-
606.4 Faucets
Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
4.10.11 Illumination Levels
The level of illumination at the car controls, platform, and car threshold and landing sill shall be at least 5 footcandles (53.8 lux)....
-
4.24.7 Faucets
Lever-operated, push-type, touch-type, or electronically controlled mechanisms are acceptable designs....
-
§100.306 Intent to operate as housing designed for persons who are 55 years of age or older.
(Approved by the Office of Management and Budget under control number 2529-0046) [64 FR 16330, Apr. 2, 1999]...
-
§100.307 Verification of occupancy.
(Approved by the Office of Management and Budget under control number 2529-0046) [64 FR 16330, Apr. 2, 1999]...
-
4.10.11 ILLUMINATION LEVELS
The level of illumination at the car controls, platform, and car threshold and landing sill shall be at least 5 footcandles (53.8 lux)....
-
4.24.7 FAUCETS
Lever-operated, push-type, touch-type, or electronically controlled mechanisms are acceptable designs....
-
§ 37.43(e)(2)(ii)
., grab bars, enlarged toilet stalls, accessible faucet controls);...