Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
Search Results "Clear Opening"
Commonly Searched Documents
-
306.3.3 Minimum Required Depth
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
4.34.5.5(1) Size and clearances
Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
2.6 Passing Spaces
ORARs with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 2.6 at intervals of 200 feet (61 m) maximum....
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
- Clarity XLC2 Amplified Cordless Phone
- Clarity XLC3.4 DECT 6.0 Extra Loud Big Button Speakerphone with Talking Caller ID and ClarityLogic™
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
11B-809.2.2 Turning space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
Ticket distribution methods. (Section-by-Section Analysis)
The proposed rule makes clear that it is meant to reach all public accommodations that provide a service by which individuals can purchase event tickets, and is not limited to a venue's...
-
Ticket distribution methods. (Section-by-Section Analysis)
The proposed rule makes clear that it is meant to reach all public entities that provide a service or system by which individuals can purchase event tickets, and is not limited to a venue's...
-
11B-809.2.2 Turning space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
11B-809.2.2 Turning space
For example, in kitchens, Section 11B-804.3.1 requires at least one work surface with clear floor space complying with Section 11B-306 to be centered beneath....
-
Passing Spaces [1016.4]
Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet....
-
Circulation Paths
Objects that overhang circulation paths do not provide clear headroom....
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)
Building Entrance: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9)....
- Magnuson Group STORLEK Waste Receptacles
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
- Sioux Chief Closet Flanges Demonstration Video
-
11B-1008.2.3 Water play components
Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
-
General: ADA Standard Section 706.1
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....