At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces that are on the same site."...
Search Results "Model Building Code"
-
11B-206.2.2 Within a site
-
1.4 Accessible Route Requirements
1.4 Accessible Route Requirements: For additions, the new construction provisions require an accessible route from the area of the addition to other accessible areas of the building, site...
-
Public entrances (Section-By-Section Analysis and Response to Comments)
- Generally, at least 50% of public entrances to new buildings must be accessible, rather than all entrances, as would often have resulted from the proposed approach....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
1.9.1.1.3
1.9.1.1.3 All publicly funded buildings used for congregate residences or for one- or two-family dwelling unit purposes shall conform to the provisions applicable to living accommodations...
-
Accessible Jury Boxes, Attorney Areas, and Witness Stands
Section 206.2.4 of the 2010 Standards requires, in new construction and alterations, at least one accessible route to connect accessible building or facility entrances with all accessible...
-
16. If, as a reasonable accommodation, an employer restructures an employee's job to eliminate some marginal functions, may the employer require the employee to take on other marginal functions that s/he can perform?
Example: A cleaning crew works in an office building. One member of the crew wears a prosthetic leg which enables him to walk very well, but climbing steps is painful and difficult....
-
4.1.6(1)(j) EXCEPTION
Any elements or features of the building or facility that are being altered and can be made accessible shall be made accessible within the scope of the alteration....
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
In addition, areas of refuge are not required in open parking garages, apartment buildings, detention and correctional facilities, or open exit stairways between floors in buildings with...
-
11B-206.6 Elevators
Exceptions: In a building or facility permitted to use the exceptions to Section 11B-206.2.3 or permitted by Section 11B-206.7 to use a platform lift, elevators complying with Section...
- Corbin Russwin Inc. Access 800 AC2 Electrified Door Hardware
-
4.3.5.2 180-degree turn
Figure 4-5: Accommodation model depicting the minimum clear width required by users of manual wheelchairs, powered chairs and scooters to complete a 180-degree turn....
- Butler Mobility Inclined Platform Wheelchair Lift
- Pilot Rock FSW-30 Campfire Ring
- The UAB-SCIMS Information Network
-
11B-202.3.1 Prohibited reduction in access
An alteration that decreases or has the effect of decreasing the accessibility of a building or facility below the requirements for new construction at the time of the alteration is prohibited...
-
1003.1 Applicability
(DSA-AC & HCD 1-AC) In addition to the requirement of this chapter, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required...
-
11B-202.3.1 Prohibited reduction in access
An alteration that decreases or has the effect of decreasing the accessibility of a building or facility below the requirements for new construction at the time of the alteration is prohibited...
-
[2010 ADAS] 105.2.2 ASME
ASME A17.1- 2000 Safety Code for Elevators and Escalators, including ASME A17.1a-2002 Addenda and ASME A17.1b-2003 Addenda (see 407.1, 408.1, 409.1, and 810.9)....
-
Section 35.150(b)(2) Safe harbor (Section-by-Section Analysis)
These revised requirements reflect incremental changes that were added either because of additional study by the Access Board or in order to harmonize requirements with the model codes....
-
4.1.6(1)(e)(ii)
(ii) alterations to one or more exterior or interior public pay telephones occur in an existing building or facility with four or more public telephones with at least one in an interior...
-
2. IMPROVING PHYSICAL ACCESS
People with disabilities should be able to travel to a health care site, approach and enter and move around the building as conveniently as everyone else....
-
Structural Frame
be considered to be the columns and the girders, beams, trusses and spandrels having direct connections to the columns and all other members which are essential to the stability of the building...
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...