spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements such as at doors...
Search Results "Smoke-Rated Door"
-
11B-304.2 Floor or ground surfaces
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The circle symbol shall contrast with the door, either light on a dark background or dark on a light background....
- Mind's Eye Travel
-
4.3.11.1(5)
) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive doors...
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
§ 38.31(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread or lift platform....
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Lighthouse International
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Locating refrigerators so that their doors can swing back 180 degrees is more convenient for wheelchair users....
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
68.10(12) Element
., telephone, curb ramp, door, drinking fountain, seating, water closet, or public right-of-way....
-
§ 37.13(b)
(b) The vehicle door height requirements for vehicles over 22 feet identified in §38.25(c) of this title apply to solicitations for vehicles under this part after January 25, 1992....
-
§ 38.63(b) Exception
Between-car barriers are not required where platform screens are provided which close off the platform edge and open only when trains are correctly aligned with the doors....
-
11B-809.7.1 Width
Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
4. Implications for Standards
It could be the roughness equivalent of the rating for "good (3.5)", "fair (2.5)", or somewhere else along the rating spectrum....
-
Section H: Lifts
(§§410.5, 309.4) H6 Is the clear width of the door opening/gate opening at the end of the lift at least 32"?...
-
106 Definitions
The following definitions have been removed as unnecessary, in most cases due to changes in certain scoping or technical requirements: "accessible route," "area of refuge," "automatic door...
-
General [9.1.1]
Where room numbers are provided, they must be raised and Brailled and located on the wall at the latch-sides of doors for safety and uniformity....
- Shelter Shutters
-
Avoid Avoidance
Disaster and emergency planning is an activity that should be integrated into our lives (the same way we are encouraged to check our smoke alarm batteries when we change the clocks for daylight...
-
1009.3 Stairways
Areas of refuge are not required for smoke protected assembly seating areas complying with Section 1029.6.2....
-
1011.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT...
-
Problem Two (Entrance)
Problem Two: The entrance door threshold is one inch high....
-
1013.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1013.1, shall be identified by a tactile exit sign with the words “EXIT...