These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
Search Results "Viewing Distance"
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
703.3.1 Dimensions and Capitalization
Measurement Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm) Distance...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance...
-
Accessible Slopes
If the distance is greater than 2 inches, the ramp is too steep. For example, if the distance is 3 inches, then the slope is 1:8 (3:24 = 1:8 which is a steeper slope than 1:12). ...
-
Sales Counters [7.2(1)]
Recommendation:Travel distances between counters and facility size should be considered where not all counters are accessible. (ADAAG does not specify maximum travel distances)....
-
Lavatories Adjacent to Partitions
In the interpretation, accessories such as hand dryers or paper towel dispensers cannot encroach into the 18” distance from the adjacent partition or wall, to the centerline of the lavatory...
-
Running Slope
This may be expressed as the percentage of change in elevation (grade) or as a ratio of vertical distance to horizontal distance (running slope)....
-
16(a)(ii)
(if the hotel offers more than one room with a premium view at a higher cost), one room on the executive level (if the hotel has an executive level), and one smoking room (if the hotel...
-
Display Screens
requirement that the display screen be visible from a point located 40 inches above the center of the clear floor space essentially means that the display screen must not be obscured from view...
-
Sloped Surfaces
While the level is in this position, measure the distance between the bottom end of the level and the sloped surface below....
-
704.5 Fire-resistance rating
The fire-resistance rating of exterior walls with a fire separation distance of greater than 5 feet (1524 mm) shall be rated for exposure to fire from the inside....
-
Spout Location [4.15.3]
Since rounded or oval bowls may not have a "front edge," a three inch distance is specified; the entire trajectory does not have to be within this distance....
-
703.3.1 Dimensions and Capitalization
703.3.1 Braille Dimensions Measurement Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm) Distance...
-
Check-Out Aisles [7.3]
Clear passage must be at least 36 inches wide continuously and 32 inches at a point (24 inch maximum distance). Access can be provided at aisles shared between two check-outs....
-
§ 36.308(a)(1)(ii)(B)
(B) Provide viewing angles to the screen, performance area, or other focal point that are equivalent to or better than the average viewing angles provided to all other spectators; * *...
- Grohe Allure Two-Hole Basin Mixer S-Size Faucet
-
15(b)
At hotels where there are two or more premium views offered, the hotel shall not be required to provide an accessible room in a particular view category if fewer than 5% of the rooms at...
-
11B-803.6 Mirrors
Mirrors shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person...
-
11B-803.6 Mirrors
Mirrors shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person...
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....