The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
Search Results "Open Captioning"
-
4.13.11* DOOR OPENING FORCE
-
Track Crossing
Section 810.10 addresses track crossings at transportation facilities. The proposed rule required route surfaces to be level with the rail top, but permitted a 2 ½ inch gap at the...
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere...
-
4.13.11(2)(b)
(b) interior hinged doors: 5 lbf (22.2N)
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door. In high-rise buildings, air-pressure differentials may require a...
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door. In high-rise buildings, air-pressure differentials may...
-
§382.51(a)(8)
newly acquire televisions and other audio-visual displays for passenger safety briefings, information, or entertainment on or after May 13, 2009, such equipment must have high-contrast captioning...
-
4.13.11(1)
(1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
3.2.2.3. High Accessibility Baseline
The High Accessibility baseline assumes that: The percentage of auditoriums equipped to provide closed movie captioning or audio description amongst auditoriums operated by surveyed...
-
3.2.2.2. Medium Accessibility Baseline
The Medium Accessibility baseline assumes that: The percentage of auditoriums equipped to provide closed movie captioning or audio description amongst auditoriums operated by all...
-
C. Costs and Benefits
For movie theaters with auditoriums exhibiting digital movies, total costs are composed of the following components: Acquisition costs for captioning hardware; Acquisition...
-
3.2.2.1. Low Accessibility Baseline
The Low Accessibility baseline assumes that: The auditoriums equipped to provide closed movie captioning or audio description as reported in the 2015 survey are the only indoor...
-
4.9.2 Treads and Risers
Open risers are not permitted....
-
4.2.3. Alternate Medium Accessibility Baseline
In addition to the uncertainty regarding the actual number of auditoriums already equipped to provide closed movie captioning or audio description (the baseline), there is also uncertainty...
-
13. Do the provisions for openings in floor and ground surfaces in Section 302.3 apply to walking surfaces in play areas?
Do the provisions for openings in floor and ground surfaces in Section 302.3 apply to walking surfaces in play areas? Yes....
-
3.2.2.4. Summary of Baselines
In the Medium Accessibility baseline, approximately 70 percent of auditoriums are equipped to provide closed movie captioning and approximately 70 percent are equipped to provide audio description...
-
Costs and Benefits
disabilities currently have consistent access to movie theaters that provide closed captioning and audio description. ...
-
§ 36.303(g)(9) Operational requirements
On or after January 17, 2017, whenever a public accommodation provides captioning and audio description in a movie theater auditorium exhibiting digital movies, it shall ensure that at least...
-
4.2.1. Low Accessibility Baseline
This baseline assumes that the auditoriums already equipped to provide closed movie captioning and audio description, as reported in NATO’s 2015 Accessibility Survey, are the only auditoriums...
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Sign language and oral interpreters
Offer sign language and oral interpreter services and realtime captioning, on advance request, for all public programs and include a notice on the Museum's website to that effect....
-
4.2.2. High Accessibility Baseline
The costs under the High Accessibility baseline are lower than in the primary analysis because more auditoriums are assumed to be equipped to provide closed movie captioning or audio description...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Door Closers [4.13.10]
Door Closers [4.13.10] Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be...