In the past, some PSAPs have required callers using TTYs to press the space bar or other keys after they call, to emit tones and notify call takers that it is a TTY call....
Search Results "On-Call Room"
-
Requiring Callers Using TTYs to Press a Key
-
11B-411.2.1.3.4 Position
The face of hall call console assemblies and the face of touch screens shall be sloped away from the user at 7 to 25 degrees from the vertical plane....
-
Transient Lodging Guest Rooms: ADA Standard Section 224
Section 224 covers scoping requirements in the current ADA Standards for transient lodging guest rooms.
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-223.1.1.1 Area alterations
Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
-
11B-223.1.1.1 Area alterations
Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
-
4.10.4(3)
(3) Signals shall be visible from the vicinity of the hall call button (see Fig. 20)....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
612 Saunas and Steam Rooms
612 Saunas and Steam Rooms...
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction....
-
407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction....
-
407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...