Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum....
Search Results "NFPA: National Fire Protection Association"
Commonly Searched Documents
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
-
11B-1003.3.2 Boarding pier clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
4.3.11.1(6)
Doors in the smoke barrier shall be tight-fitting smoke- and draft-control assemblies having a fire-protection rating of not less than 20 minutes and shall be self-closing or automatic closing...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. [2010 ADA Standards] 215.1 General....
-
ANSI Standard
The American National Standards Institute (ANSI) is a private, national organization, and is not connected with the Federal Government....
-
ADA Facilities Compliance Continuing Education Courses & Resources
ADA Facilities Compliance Continuing Education Courses & Resources by Evan Terry Associates, P.C....
-
Scoping [4.1.3(13)]
illustrate the coverage of this section: element compliance alarm pull stations required as fixed element for common use by building occupants fire...
-
907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....
-
907.2.5 Group H
A manual fire alarm system shall be installed in Group H-5 occupancies and in occupancies used for the manufacture of organic coatings....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by...
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10. Low-energy and power-assisted doors shall...
- TelCom Wheelock Wall Mount Chime - 24 VDC 15/75 on Axis Strobe Candela CH70-241575W-FR
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side....
-
G. ANSI/AAMI HE 75
In 2009, the Association for the Advancement of Medical Instrumentation issued ANSI/AAMI HE 75, a recommended practice on human factors design principles for medical devices....
-
Power-Assisted Doors and Gates [§404.3]
Power-Assisted Doors and Gates [§404.3] Power-assisted devices reduce the opening force of doors with closing mechanisms. They are activated by initial manual force, switches, or...
-
907.1.2 Equipment
Systems and their components shall be listed and approved for the purpose for which they are installed.
-
[F] 907.5 Occupant notification systems
[F] 907.5 Occupant notification systems. ...
-
III-7.5160 Alarms
III−7.5160 Alarms (ADAAG §4.1.3(14)). Both audible and visual alarms are required when emergency warning systems are provided. ADAAG has detailed requirements concerning features...
-
[F] 907.5 Occupant notification systems
...
-
4.1.7(2)(d) Certified Local Government Historic Preservation Programs
delegated the consultation responsibility for purposes of this section to a local government historic preservation program that has been certified in accordance with section 101(c) of the National...