Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
Search Results "Leg Supports"
Commonly Searched Documents
- 
    
  
  M305.2.7 Clearance
  
- 
    
  
  M305.2.4 Cross Section
  Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.... 
- 
    
  
  M305.2.1 Location (Section-by-Section Analysis)
  The Committee recommended requiring one support on the opposite side of the transfer side regardless of whether it was a transfer support or positioning support.... 
- 
    
  
  M305.2.5 Surface Hazards
  Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.... 
- 
    
  
  Service Animal Issues
  Another important issue that a number of commenters raised concerned “emotional support animals.”... 
- 
    
  
  Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
  Requires the Premium User plan or above. (Login or upgrade your account!)
- 
    
  
  M305.2.1 Location
  Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position.... 
- 
    
  
  Conclusion
  During this second phase of the independent wheelchair transfer study, platform transfers with and without grab-bars and a backrest and two-step transfers were evaluated. The study... 
- Service and Companion Animal Owners: Know Your Rights!
- 
    
  
  Implication for Standards and Design
  Each phase involved a highly customized transfer station iteratively developed with scientific, expert and consumer input to support the goals of the project. ... 
- 
    
  
  M305.2.3 Height
  During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed transfer surface... 
- 
    
  
  M305.2.5 Surface Hazards (Section-by-Section Analysis)
  The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports.... 
- 
    
  
  (1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
  This revision to provide options for two types of transfer surfaces necessitated adding additional technical criteria addressing transfer surface size (M301.2.3) and transfer supports (M305.2... 
- Mockett TLRAL27 Roma Series Adjustable Table Leg
- 
    
  
  M305.2.4.1 Circular Cross Section
  Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- Mockett TLKNB27 Original Kyros Leg 5" Base
- 
    
  
  Examples of access:
  Exam table that lowers to 17-19 inches from the floor Many people find these tables easier to use. There are many ways to help people get access. See the [images]... 
- 
    
  
  ADA Requirements - Service Animals
  U.S. Department of Justice Civil Rights Division Disability Rights Section Service Animals The Department of Justice published revised final regulations implementing the... 
- 
    
  
  M305.2.4.2 Non-Circular Cross Section
  Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches... 
- Mockett TLEL3 Electrically Driven Adjustable Table Legs
- 
    
  
  d. Unobstructed Transfer
  Six of the eleven commenters who responded to this question supported permitting equipment parts to extend up to three inches horizontally beyond the edge of the transfer surface.... 
- Big John Toilet Support & Short Swivel Support informational video
- Big John Toilet Support & Short Swivel Support 7.5" to 14" Installation Video
- HEWI Hinged Support Rail Duo
 
              