Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
Search Results "Hoistway Clearance"
Commonly Searched Documents
-
Clear Width [4.13.5] and Vertical Clearance
-
R405.1 General
Clearances are measured in relation to the usable clear space, not necessarily to the vertical support for an element....
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
804.2 Clearance
804.2 Clearance. Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
11B-407.3.4 Door and signal timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
11B-407.3.4 Door and signal timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
407.3.4 Door and Signal Timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
407.3.4 Door and Signal Timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
11B-407.3.4 Door and signal timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
Bedside Clearances
Bedside Clearances Clearance at least 36 inches wide is required on each side of beds. Where more than one bed is provided, this space can overlap....
-
Philips Healthcare
recommendations included in the Advisory Committee Report dated September 13th, 2013 represent the consensus of the committee With the following exceptions: 1) NPRM M303.2.4 Knee and Toe Clearance...
-
11B-306.2.5 Width
Toe clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.2 TOE CLEARANCE...
-
11B-306.3.5 Width
Knee clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.3 ‡‡ KNEE CLEARANCE...
-
407.3.4 Door and Signal Timing
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway...
-
306.2.5 Width
Toe clearance shall be 30 inches (760 mm) wide minimum. Figure 306.2 Toe Clearance...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
R405.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear space, the toe clearance shall extend 430 mm (1.4 ft) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306....