Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
Search Results "Elevator Car Designation"
Commonly Searched Documents
-
407.4.6.2 Buttons
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush.
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
Destination-Oriented Elevators
Lobby indicators designate which car to use, which is programmed by the time of arrival. This type of elevator reduces the number of stops per trip....
-
Illumination Levels: ADA Standard Section 409.4.5
Section 409.4.5 covers the current ADA Standards for the illumination of the elevator car in private residence elevators.
- Otis Elevator Advanced Lantern Retrofit
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....