Water closets and toilet compartments shall comply with Sections 11B-604.2 through 11B-604.8....
Search Results "Compartment Width"
Commonly Searched Documents
-
11B-604.1 General
-
11B-604.1 General
Water closets and toilet compartments shall comply with Sections 11B-604.2 through 11B-604.8....
-
1018.5 Aisles in other than assembly spaces and Groups B and M
than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served, but the width...
- Amramp Wheelchair Ramps and Mobility Solutions
-
11B-703.8.6 Stroke width
The uppercase letter “I” shall be used to determine the allowable stroke width of all low resolution VMS characters of a font....
-
1009.2.5 Seat Width
The seat shall be 16 inches (405 mm) wide minimum.
-
1009.2.5 Seat Width
The seat shall be 16 inches (405 mm) wide minimum.
-
4.3.5.1 90-Degree Turn
The width of circulation spaces should be wider to accommodate two-way traffic and egress requirements....
-
Clear Width [§405.5]
Clear Width [§405.5] Ramp runs must have a clear width of 36” minimum (measured between handrails where provided)....
-
A. Door Width
Door Width....
-
Handrails: ADA Standard Section 1009.3.3
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
3.3.10 90-Degree Turn
The width required for all participants to complete a 90-degree turn in our sample was much smaller than the UDI findings (Figure 3‒10), due to differences in the abilities of people or/...
-
404.3.1 Clear Width
404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
H. Stall Door
H. If the accessible toilet is in a stall, is the stall door positioned diagonally opposite, not directly in front of, the toilet so persons who use wheelchairs may pull fully into...
-
4.17.1 Location
Accessible toilet stalls shall be on an accessible route and shall meet the requirements of 4.17.
-
4.17.1 LOCATION
Accessible toilet stalls shall be on an accessible route and shall meet the requirements of 4.17.
-
11B-403.5.1 Clear width
The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that...
-
11B-403.5.1 Clear width
Exceptions: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated...
-
§ 38.113(a) Clear width
(a) Clear width....
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General....
-
608.1 General
Shower compartments shall comply with 608. Advisory 608.1 General....