The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space.
Search Results "Bed Height"
-
1014.2.1.2 Floor Height
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches....
-
M302.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A....
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height...
- Pressalit Care 3000 Adult Changing Table
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments....
-
Adjustable Height Range Considered
See Analysis of Seat Heights for Wheeled Mobility Devices at: http://udeworld.com/analysis-of-seat-height-for-wheeled mobility-devices....
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
Changes in Level and Horizontal Gaps
This height allows for freight passage while reducing the height of the first step of a rail car above the platform....
-
MITA Advisory Committee Members
MITA Advisory Committee Members MINORITY REPORT ON TRANSFER SURFACE HEIGHT RECOMMENDATIONS OF THE U.S. ACCESS BOARD ADVISORY COMMITTEE RE: NPRM: M301.2.1 AND M302.2.1 HEIGHT...
-
11B-703.8.4 Character height
11B-703.8.4 Character height. The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
11B-703.8.4 Character height
11B-703.8.4 Character height. The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
- PC 2000 Hi Lo Adult Changing Table
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height...
-
4.1 Wheeled Mobility Device Dimensions
larger than for armrest height and handle height....
-
11B-703.8.4 Character height
The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
F. Counter Height
F. Do the registration counters or other counters serving guests have a lowered portion no more than 36" high or is there a folding shelf at 36" high to allow persons who use...
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...