building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable...
Search Results "Adaptive Sports"
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
-
B. Agreement of the Parties
Ellerbe has participated in the design of assembly areas, sports stadiums and arenas that have been or will be occupied after January 26, 1993. 4....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Each accessible dwelling unit with adaptable features where sanitary facilities are located within the unit or suite must provide at least one bathroom complying with the definition of “...
-
11B-809.8 Doors
New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Language addressing interior doors within residential dwelling units with adaptable...
-
In-swinging Bathroom Doors
Adjusting an in-swinging door to swing out is the type of later adaptation that can be made fairly easily by a resident or tenant....
-
11B-203.8 Residential facilities
housing residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-203.8 Residential facilities
housing residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length...
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
11B-809.8.3 Door maneuvering clearance.
Minimum maneuvering clearances at doors shall comply with Section 11B-809.8.3. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge...
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-206.7.6 Guest rooms and residential dwelling units
to provide mobility features complying with Section 11B-806.2 or residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-206.7.6 Guest rooms and residential dwelling units
to provide mobility features complying with Section 11B-806.2 or residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-206.7.6 Guest rooms and residential dwelling units
to provide mobility features complying with Section 11B-806.2 or residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 or adaptable...