11B-705.1.2.5 Blended transitions. Detectable warnings at blended transitions shall be 36 inches (914 mm) in width.
Search Results "Clear Floor Area"
-
11B-705.1.2.5 Blended transitions
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
-
1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1. Handrails shall not be required on ramps...
-
1008.2.5.3 Handrails
1008.2.5.3 Handrails. Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1. Handrails shall not be...
-
221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
§ 38.93(b) Passageways
(b) Passageways. A route at least 32 inches wide shall be provided from doors required to be accessible by paragraph (a)(1) of this section to seating locations complying with...
-
§ 38.95(a)(1) General
(1) General. All new commuter rail cars, other than level entry cars, covered by this subpart shall provide a level-change mechanism or boarding device (e.g., lift, ramp or bridge...
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
1003.3.1 Boat Slip Clearance
Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADAS] 219.2 Required Systems. ...
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADAS] 219.2 Required Systems. ...
-
1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
The sale of any seats in the covered area requires removal of the platform, thereby eliminating some of the required wheelchair seating locations. ...
-
12.1 Q...How is the individual building test performed for additional stories, to determine if those stories must also be treated as ground floors?
For purposes of determining whether a non-elevator building has more than one ground floor, the point of measurement for additional ground floors, after the first ground floor has been established...
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADA Standards] 219.2 Required Systems....