Section 403.5 specifies a continuous clearance of 36 inches minimum for walking surfaces....
Search Results "Trail Surface"
-
Clearance
-
M307.2 Tactilely Discernible (Section-by-Section Analysis)
Patients who are blind or have low vision have difficulty distinguishing a flat membrane button or similar control unless it is tactilely discernible from the surrounding surface and any...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
Location and Size
The side rails are 20 inches minimum in length, 6 inches minimum in height above the table surface, and 1 inch measured horizontally from the adjacent edge of the table surface....
-
3.2 Study Limitations and Other Issues
warning surface and the luminance contrast of the warning surface with adjacent surfaces....
-
R208.1 Where Required
Detectable warning surfaces complying with R305 shall be provided at the following locations on pedestrian access routes and at transit stops: 1....
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
Seat Height
Commenters noted that this specification should be clarified as applying to the height as measured at the top of the seat surface. Response....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
R405.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear space, the knee clearance shall be 280 mm (11 in) deep minimum at 230 mm (9 in) above the finish surface, and 205 mm...
-
Illumination Levels (Reserved) [4.30.8]
A level from 10 to 30 footcandles is recommended uniformly over the sign surface....
-
9. Outdoor Developed Areas
The new provisions address access to trails, picnic and camping areas, viewing areas, beach access routes and other components of outdoor developed areas on federal sites when newly built...
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
9. Outdoor Developed Areas
The new provisions address access to trails, picnic and camping areas, viewing areas, beach access routes and other components of outdoor developed areas on federal sites when newly built...
-
End of Document
Military Trail West Palm Beach, FL 33415...
-
9. Outdoor Developed Areas
The new provisions address access to trails, picnic and camping areas, viewing areas, beach access routes and other components of outdoor developed areas on federal sites when newly built...
-
9. Outdoor Developed Areas
The new provisions address access to trails, picnic and camping areas, viewing areas, beach access routes and other components of outdoor developed areas on federal sites when newly built...
-
9. Outdoor Developed Areas
The new provisions address access to trails, picnic and camping areas, viewing areas, beach access routes and other components of outdoor developed areas on federal sites when newly built...
-
Appendix D: Photometric Measurements
that would be reflected from a perfectly diffusely reflecting surface....
-
Finish and Contrast: ADA Standard Section 703.6.2
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
11B-605.5.4 Toe Clearance
Partition components at toe clearances shall be smooth without sharp edges or abrasive surfaces....