Covered multifamily dwellings means buildings consisting of 4 or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
Search Results "Ground Floor Exit"
-
§100.201 Covered multifamily dwellings
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
Protruding Objects [4.31.4]
., 27 inches high from the floor), can be a hazard to people with vision impairments....
- TownSteel ED5500F Grade 1 Fire Rim Device
-
Reach Ranges and Operability Requirements
or ground (figures 50 and 51)....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
4.6.3 Eyepiece
telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm) maximum above the floor...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-106.5 Defined terms
TRANSITION BOARDING PIER BOAT LAUNCH RAMP BOAT SLIP BUILDING BUILDING OFFICIAL CATCH POOL CCR CHARACTERS CHILDREN’S USE CIRCULATION PATH CLEAR CLEAR FLOOR...
-
[2010 ADAS] 105.2.4 ICC/IBC
The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge....
-
F105.2.4 ICC/IBC
The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge....
-
105.2.4 ICC/IBC
The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge....
-
105.2.4 ICC/IBC
The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge....
-
ICC/IBC
The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge....
-
4(3)
unit that is served by the building elevator (a) is the primary entry to the unit; (b) complies with Requirements 2 through 7 with respect to the rooms located on the entry/accessible floor...
-
Recessed Objects
Alcoves must be sized to accommodate required clear floor space at accessible elements....
-
303 Changes in Level
Section 303 addresses vertical changes in level in floor or ground surfaces. No changes have been made to this section....
-
Constructed Features in Recreation Sites
If constructed features are replaced, but the ground under the feature isn't changed, the surface and slope of the ground under the feature doesn't have to be brought into conformance with...
-
11B-1002.5 Amusement ride seats designed for transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
1002.5 Amusement Ride Seats Designed for Transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
1002.5 Amusement Ride Seats Designed for Transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....