Consequently, the entities involved can limit their key station planning process to issues concerning the timing of key station accessibility....
Search Results "Floor Plan"
-
Section 37.53 Exception for New York and Philadelphia
-
11B-233.3.4.2 Alterations to individual residential dwelling units
A substantial alteration to a kitchen or bathroom includes, but is not limited to, alterations that are changes to or rearrangements in the plan configuration, or replacement of cabinetry...
-
G. Supplies
Provide an effective way for people to request and receive durable medical equipment and medication.Despite advance planning, some people with disabilities will find themselves in...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
A. ACCESSIBLE SEATING
Wheelchair Spaces shall be thirty six (36) inches wide (or as otherwise required by Section 802), located on a level floor surface, and shall adjoin accessible routes. ...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
Protrusions
Where a wheelchair space is located on a ride, nothing may protrude into the front of the wheelchair space 9 inches from the floor....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
Do all state and local buildings need to be accessible (comply with the ADA Standards for Accessible Design?)
In a two story town hall built in 1968 that doesn’t have an elevator, staff on the second floor could meet with citizens on the first floor if meeting space is comparable to that on the...
-
M303.2.4.2 Knee Clearance
Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm) minimum...
-
Car Position Indicators [4.10.13]
Verbal announcements must announce each floor a car stops at but not each floor passed....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
Drinking Fountain Scoping for Exterior Sites
In the final rule, scoping has been clarified as applying to units provided at "exterior sites," in addition to those installed on floors....
-
III. STRUCTURAL MODIFICATIONS TO WHC BUILDINGS AND FACILITIES
for the Accessible Patient Rooms in the Tower prior to such plans becoming final....
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...