Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
Search Results "DSA-AC: California Division of the State Architect – Access Compliance"
Commonly Searched Documents
-
11B-604.8.2.1 Size
-
11B-206.2.9.2 Wheelchair spaces, ride seats designed for transfer, and transfer devices
spaces complying with Section 11B-1002.4, amusement ride seats designed for transfer complying with Section 11B-1002.5, and transfer devices complying with Section 11B-1002.6 shall be on an accessible...
-
Elevated Dune Crossings
An dune crossing that is elevated or has a slope that exceeds 1:20 (5 percent) that is part of a beach access route must have handrails and edge protection (figure 118)....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided, except...
-
1.1.8 City, county or city and county amendments, additions or deletions
Local modifications shall comply with Health and Safety Code Section 18941.5 for Building Standards Law, Health and Safety Code Section 17958 for State Housing Law or Health and Safety Code...
-
Trail
A pedestrian route provided primarily to connect elements, spaces, or facilities within a site is not a trail; it is an outdoor recreation access route (ORAR)....
- Sculpted Single-hole Touchless AC-powered Commercial Bathroom Sink Faucet
-
382.65 What are the requirements concerning on-board wheelchairs?
In aircraft with more than 60 passenger seats, carriers must provide an onboard wheelchair if the aircraft has an accessible lavatory....
-
Conclusions
Gathering more evidence on these issues will help to determine what the limits of setup should be in order to refine current accessibility standards related to transfers in the built environment...
-
233.3.1.1 Residential Dwelling Units with Mobility Features
at least 5 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide mobility features complying with 809.2 through 809.4 and shall be on an accessible...
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
§ 382.1 Purpose
The purpose of this part is to implement the Air Carrier Access Act of 1986 (49 U.S.C. 41705), which provides that no air carrier may discriminate against any otherwise qualified individual...
- Seton Optima Men Restroom Sign
-
68.101(c)(5)(B) Accessible route from parking area(s)
(B) An accessible route from the parking area(s) shall comply with TAS 206 and 402....
-
9.5.3 Accessible Sleeping Accommodations in New Construction
Accessible sleeping rooms shall be provided in conformance with the table in 9.1.2 and shall comply with 9.2 Accessible Units, Sleeping Rooms and Suites (where the items are provided)....
-
Section 36.303(g)(5) Performance Requirements for Captioning Devices and Audio Description Devices
Proposed § 36.303(g)(2)(iii)(B) stated that the individual devices needed to be adjustable; be available to patrons in a timely manner; provide clear, sharp images; be properly maintained...
-
N1
Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the health units and medical care areas (it may narrow to 32 inches wide for...
-
Required Compliance [§209]
Required Compliance [§209] Where passenger loading zones are provided, at least one accessible passenger loading zone is required in every continuous 100 linear feet of loading zone or...
-
Colorado Cross-Disability Coalition, et al. Plaintiffs, v. Abercrombie & Fitch Co., et al., Defendants. - Statement of Interest on the Parties' Motions for Summary Judgment
IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF COLORADO Civil Action No. 09-cv-02757-WYD-KMT COLORADO CROSS-DISABILITY COALITION, et al. ...
-
Architectural Barriers Act
The accessibility standards issued by the General Services Administration adopt, without any additions or modifications, the Access Board’s current guidelines, which are discussed below...
-
Accessible Routes
Accessible Routes Accessible routes are continuous, unobstructed paths connecting all accessible elements and spaces of a building or facility....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
Maintenance
While this is not addressed by ADAAG, the Department of Justice's title III rule requires that accessible features and equipment be maintained in operable condition....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...