Windows requiring pushing, pulling, or lifting to open (for example, double-hung, sliding, or casement and awning units without cranks) should require no more than 5 lbf (22.2 N) to open...
Search Results "Door Opening Angle"
Commonly Searched Documents
-
A4.12.2 Window Hardware
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
13) Detectable warnings
13) Detectable warnings ADAAG: Required on curb ramps, hazardous vehicular areas, and reflecting pools, but not on doors to hazardous areas....
- Nora Systems, Inc. Norament Round Stairtreads
-
11B-809.10.6.1 Size
unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep with an entrance opening...
-
11B-227.2 Check-out aisles
When check-out aisles are open for customer use, the business should ensure that a minimum of one accessible check-out aisle is always available for use by persons with disabilities....
-
704.2.3 Combustible projections
Combustible projections located where openings are not permitted or where protection of openings is required shall be of at least 1-hour fire-resistance-rated construction, Type IV construction...
- American Specialties Adjustable Tilt Mirror 0600T
- Stabila, Inc. Magnetic Tech Digital Electronic Level Type 96M-2
-
704.10 Vertical exposure
For buildings on the same lot, approved protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent...
-
§ 36.303(g)(6)(ii)
(ii) A public accommodation may use open movie captioning as an alternative to complying with the requirements specified in paragraph (g)(3) of this section, either by providing open movie...
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
- AJW Architectural Products U6084 Unidoor Folded Towel Dispenser & Waste Receptacle Combination - Recessed
- Pilot Rock BPR1 Bear Resistant Trash Receptacle
- Door King Inc. 6004 Column Mount Swing Gate Operator
- Door King Inc. VoIP Integration for Entry and Access Control Systems
- Jacknob Corp. 6409 ADA Latch & Strike Combo for Inswinging Door
-
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
- Pilot Rock BPR2 Bear Resistant Trash and Recycling Receptacle
- AJW Architectural Products U5814 Unidoor 1.5 Gallon Sanitary Napkin Disposal - Recessed
-
FIGURE INDEX
FIGURE INDEX Figure 104 Graphic Convention for Figures Figure 302.2 Carpet Pile Height Figure 302.3 Elongated Openings in Floor or Ground Surfaces Figure 303.2 Vertical Change...
- Bobrick TrimLineSeries Recessed Seat Cover Dispenser B-3013