A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of a beach access route....
Search Results "Building Permit"
-
6.7.1.3
-
1017.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1014.2.1.1.2 Slope
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 shall be permitted where necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1011.2.3 Slope
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
403.5 Clearances
EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential to the...
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
407.3.2 Operation
EXCEPTION: Existing manually operated hoistway swing doors shall be permitted provided that they comply with 404.2.3 and 404.2.9....
-
§100.203(c)
It is unlawful for the landlord to refuse to permit the tenant, at the tenant's own expense, from making the modifications necessary to add the grab bars....
-
407.4.1 Car Dimensions
that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and a clear width 36 inches (915 mm) minimum shall be permitted...
- Kompan, Inc. M584 - Starfish Tables and Benches
- Seton California Code ADA Men Rest Room Sign with Larger ISA - Black
-
[2010 ADAS] 105.2.2 ASME
The building location, the elevator car number, and the need for assistance must be provided to authorized personnel answering the emergency call....
-
[2010 ADAS] 105.2.2 ASME
The building location, the elevator car number, and the need for assistance must be provided to authorized personnel answering the emergency call....
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
§382.45(b)(3)
., West Building, Room W96-432, Washington, DC 20590, and...
-
§301(7)(A)
An inn, hotel, motel, or other place of lodging, except for an establishment located within a building that contains not more than five rooms for rent or hire and that is actually occupied...
-
Sec. 469.003(a)(1)
(1) a building or facility used by the public that is constructed, renovated, or modified, in whole or in part, on or after January 1, 1970, using funds from the state or a county, municipality...
-
Sec. 469.059(a)
(a) The department shall continue to monitor a complaint made under Section 51.252, Occupations Code, that alleges that a building or facility is not in compliance with the standards and...
-
Public Use Areas
DEFINITION NOTES Public Use Areas Amends prior model code definition to clarify that public use areas include areas associated with “buildings...
-
12181(7)(A)
(A) an inn, hotel, motel, or other place of lodging, except for an establishment located within a building that contains not more than five rooms for rent or hire and that is actually occupied...
-
4.1.6(1)(e)(i)
(i) alterations to existing buildings or facilities with less than four exterior or interior public pay telephones would increase the total number to four or more telephones with at least...
-
4.1.3(8)(a)(ii)
(ii) Accessible entrances must be provided in a number at least equivalent to the number of exits required by the applicable building/fire codes....