Following a stay in a rehab center, the architect realized that most hospitals ignore critical resident needs. He set out to change all that with attractive, efficient,...
Search Results "Wheelchair Space (Medical Diagnostic Equipment)"
Commonly Searched Documents
- Michael Graves at TEDMED 2011
- Accessible Pittsburgh: Hospital Compliance Guidelines
- No Barriers USA
-
Using a Fitness Center Does Not Have to be an Exercise in Frustration: Tips for People with Mobility and Visual Disabilities
Professions Western University of Health Sciences jik@pacbell.net Version 1.1, November 2008 The Rehabilitation Engineering Research Center (RERC) on Accessible Medical...
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
5.3.5 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1. ...
-
UFAS vs. ADAAG Comparison
Elevator req'd to serve each level in all multi-story bldgs. by UFAS but not for certain private entity bldgs. under ADAAG. 4.1.2(18)a Number of req'd wheelchair...
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
4.1 Wheeled Mobility Device Dimensions
In the U.S., as the average weight of the population has increased, wheelchair manufacturers started producing wheelchairs with larger capacity and many more seat widths. ...
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
806 Transient Lodging Guest Rooms
Substantive changes made to this section revise requirements for: vanity counter spaces in accessible toilet or bathing rooms (806.2.4.1) wheelchair turning space (806.2.6...
-
502 Parking Spaces
[See subsections ...]
-
502 Parking Spaces
[See subsections ...]
-
502 Parking Spaces
[See subsections ...]
-
§382.51(b)(2)
(2) You may meet this obligation through any combination of facility accessibility, auxiliary aids, equipment, the assistance of personnel, or other appropriate means consistent with the...
-
F244.4 Pull-up Spaces for Recreational Vehicles at Dump Stations
Where provided, pull-up spaces for recreational vehicles at dump stations shall comply with 1012.2, 1012.4, and 1012.5....
-
5.1 Transfer Surface Height Recommendations
5.1 Transfer Surface Height Recommendations Description: The transfer height is set above the finished floor surface to permit transfers form mobility devices onto the transfer...
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height