[54 FR 3283, Jan. 23, 1989, as amended at 56 FR 11665, Mar. 20, 1991; 73 FR 63616, Oct. 24, 2008]
Search Results "Mechanical Access Parking Garage"
Commonly Searched Documents
-
§100.205 Design and construction requirements.
-
§100.205(e)
(e)
-
Re: Husky 24" Line Generator Digital Laser Level
See Bill Hecker, AIA, Kirola vs City and County of San Francisco, Expert for DOJ, testimony with regards to Laser level lengths.
-
Are stairs in residential dwelling units covered by the Standards required to comply?
Yes, stairs that are part of a means of egress must comply in mobility accessible residential dwelling units covered by the Standards....
-
§104.23(a) Design and construction
or part of a facility constructed by, on behalf of, or for the use of a recipient shall be designed and constructed in such manner that the facility or part of the facility is readily accessible...
-
1018.7.2 Cross Slope
This section requires the cross slope of beach access routes to not be steeper than 1:48....
-
6.7.2 Cross Slope
The cross slope of a beach access route shall be no more than 1:33 (3 percent)....
- Bon® Tool Co. Aloha Slope Checker
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
§ 38.123(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids complying with §38.125(d) of this part and shall be connected...
- Access Board: Exit Signs
-
Adding an elevator for barrier removal trigger POT upgrades?
Site topography requires removal of barrier by adding an elevator, does this trigger POT upgrades to the area of work?
-
11B-213.3.1 Toilet compartments
213.3.1 Toilet compartments Corrects drafting error in prior code adoption to require that the fixture count for determining when additional accessible...
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
- The A11Y Project
-
Do facilities in remote locations have to be accessible?
If the Forest Service builds a facility, even in remote areas or areas that are difficult to access (including wilderness), the facility must be accessible, with few exceptions....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
- Voters with Disabilities: Additional Monitoring of Polling Places Could Further Improve Accessibility