A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
Search Results "Fire Door"
Commonly Searched Documents
-
11B-809.5.5.2 Identification
-
§382.119(b)
., fire or bomb threat)....
-
1007.8.1 System requirements
Two-way communication systems shall provide communication between each required location and a central control point location approved by the fire department....
-
12. Staff
.: installing bathtub seats, lowering adjustable shower wands, placing folding seats in transfer showers in the down position, installing auxiliary fire alarm strobes into the building alarm...
-
11. Protruding Objects in the Circulation Path
.: fire extinguishers, wall mounted lights, electrical meters, signs, pay phones, trees, shrubs, etc.) that pose a hazard to blind persons and persons with low vision by projecting into...
-
Resources:
Emergency Evacuation Planning Guide for People with Disabilities, 2016, National Fire Protection Agency Emergency Evacuation Preparedness: Taking Responsibility for Your Safety, A Guide...
- ThyssenKrupp Elevator Signa 4 Signal Fixtures
-
1.1.1 Title
Electrical Code Part 4 – California Mechanical Code Part 5 – California Plumbing Code Part 6 – California Energy Code Part 8 – California Historical Building Code Part 9 – California Fire...
-
E1-g
At each location on the way to each shelter activity area where the accessible route passes through a door, does at least one door meet the following requirements? Yes No...
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
1010.1.9.7 Delayed egress locks
A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: 6.1....
-
611 Washing Machines and Clothes Dryers
The proposed rule required the door of top loading machines and the door opening of front loading machines to be 34 inches maximum above the floor (611.4)....
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
4.34.6.7* OVENS
For side-opening ovens, the door latch side shall be next to the open counter space, and there shall be a pull-out shelf under the oven extending the full width of the oven and pulling out...
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
The triangle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
§382.53(b)
., fire, bomb threat)....
-
E2-a
Items to check include wall-mounted fire extinguishers, light fixtures, coat hooks, shelves, drinking fountains, and display cases....
-
4.3.11.1(7)
Pressurization equipment and its duct work within the building shall be separated from other portions of the building by a minimum two-hour fire-resistive construction....
-
2.1 Parking
Are there accessible paths from the parking, drop off areas, or transit stops without stairs or other items blocking access (utility boxes and poles, fire hydrants, etc.)? ...
-
Thresholds at Doorways [4.13.8]
Thresholds at Doorways [4.13.8] Thresholds complicate wheelchair maneuvering through doors, especially at doors equipped with closers....
-
TABLE OF CONTENTS
MEANS OF EGRESS SECTION 1008 DOORS, GATES AND TURNSTILES SECTION 1009 STAIRWAYS SECTION 1010 RAMPS SECTION 1011 EXIT SIGNS SECTION 1012 HANDRAILS SECTION 1013 GUARDS...
-
Signing Ceremony for Americans with Disabilities Act (July 26, 1990)
Requires the Registered User plan or above. Login!