technologies—including analog and digital televisions, tuners, personal video display devices, converter boxes, and computer equipment—by requiring such technologies to support closed and open...
Search Results "Clear Opening"
-
411.1 General (Section-by-Section Analysis)
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
-
Temporary Solutions for Election Day - Hallways and Corridors - Voters Who are Blind or Who Have Low Vision
Problem Three: The bottom of a stair is open and voters who are blind or who have low vision can hit their heads on the underside of the stair....
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
M9
[ADA Standards § 4.19.2] Yes No Notes: 1. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
1015.3 Viewing Space
This section requires each distinct viewing location to provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable base cabinets...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
- Gamco Automatic Wall Mounted Liquid Soap Dispenser - G-950SA
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
4.8.4(2)
(2) The landing length shall be a minimum of 60 in (1525 mm) clear....
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
-
Imaging equipment with bores
Diagnostic scanning equipment using magnets, x-rays, or detectors into which a patient and the table on which the patient lies is inserted into the equipment through a cylindrical opening...
-
Sec.36.303(b)(1)
transcription services, written materials, telephone handset amplifiers, assistive listening devices, assistive listening systems, telephones compatible with hearing aids, closed caption decoders, open...
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
A4.13.9 Door Hardware
Some disabled persons must push against a door with their chair or walker to open it....
-
R204.1 General
The Federal Highway Administration (FHWA) has issued guidance on the obligations of state and local governments to keep pedestrian access routes open and usable throughout the year, including...
-
A4.1.3(9)
A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power supplies for...
-
Section 508
Section508.gov opening doors logo....
-
Surface Smoothness
The standards limit changes in level and openings in floor and ground surfaces, but they do not further address overall surface smoothness....
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
§ 38.31(c)
(c) The vehicle doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination...