The outer barrier on the outboard of the lift shall automatically rise or close, or a supplementary system shall automatically engage, and remain raised, closed, or engaged at all times...
Search Results "Automatic Door"
Commonly Searched Documents
-
§ 38.83(b)(5) Platform barriers
-
§ 38.125(b)(5) Platform barriers
The outer barrier of the lift shall automatically rise or close, or a supplementary system shall automatically engage, and remain raised, closed, or engaged at all times that the lift platform...
-
§ 38.23(b)(5) Platform barriers
The outer barrier of the lift shall automatically raise or close, or a supplementary system shall automatically engage, and remain raised, closed, or engaged at all times that the platform...
-
§ 38.159(b)(5) Platform barriers
The outer barrier of the lift shall automatically raise or close, or a supplementary system shall automatically engage, and remain raised, closed, or engaged at all times that the platform...
-
§ 38.95(b)(5) Platform barriers
The outer barrier of the lift shall automatically rise or close, or a supplementary system shall automatically engage, and remain raised, closed, or engaged at all times that the lift platform...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
Door King Inc. 1837 PC Programmable IM Server Overview
Requires the Registered User plan or above. Login!
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
-
Information technology (Preamble, Section-by-Section Analysis)
The definition of information technology is identical to that in the Clinger-Cohen Act, that is, any equipment or interconnected system or subsystem of equipment, that is used in the automatic...
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-208.3.3.2
A door leading directly from the residential dwelling unit which immediately enters the garage. 2. ...
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11.2 Q. Under the individual building test, at what point of the planned entrance is the measurement taken?
On a horizontal plane, the center of each individual doorway should be the point of measurement when measuring to an arrival point, whether the doorway is an entrance door to the building...
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms: ADA Standard Section 213.2.1
Section 213.2.1 covers scoping requirements in the current ADA Standards for unisex (single-use or family) toilet and unisex bathing rooms.
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....