distribution of goods to the public, an auxiliary counter or a portion of the main counter shall be provided with a maximum height of between 28 in to 34 in (710 mm to 865 mm) above the floor...
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
7.2 SERVICE COUNTERS
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
11B.707.7.1.2 Angle-mounted display screen
away from the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
Water Play Components: ADA Standard Section 1008.2.3
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
- Grohe Concetto Single-Lever Basin Mixer 1/2" L-Size Faucet
- American Standard Brandon Centerset Bathroom Faucet
- Lynx Grills Inc. 30” Grill ProSear Burner & 1 Stainless Steel Burner (L500ADA)
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B.707.7.1.3 Horizontally mounted display screen
and no more than 90 degrees (horizontal) tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
4.13.8* Thresholds at Doorways
Raised thresholds and floor level changes at accessible doorways shall be beveled with a slope no greater than 1:2 (see 4.5.2)....
-
Lavatories and Mirrors [4.19]
In those few toilet or bathrooms permitted to be adaptable, base cabinetry is allowed as long as required clear floor space and knee and toe clearances are available when the cabinet is...
-
Performing Areas
Performing areas include spaces typically elevated or depressed and used primarily for purposes of entertainment, including stages, arena floors, and orchestra pits....
-
4.13.8* THRESHOLDS AT DOORWAYS
Raised thresholds and floor level changes at accessible doorways shall be beveled with a slope no greater than 1:2 (see 4.5.2)....
-
Can stair treads and risers be perforated?
Stair treads must meet requirements for floor or ground surfaces which specify that surface openings not allow passage of a sphere more than ½ inch in diameter (§302.3)....
-
§ 38.73(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....