Search Results "Weather Shelter"
-
9.5 Transient Lodging in Homeless Shelters, Halfway Houses, Transient Group Homes, and Other Social Service Establishments
-
K3
Tables can be relocated as needed during operation of the shelter....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction. EXCEPTION: Where the floor surface is other than asphalt, concrete, or boards, slopes not steeper...
-
f-vi
f-vi. Are the controls and operating mechanisms usable with one hand without tight grasping, pinching, or twisting? [ADA Standards §§ 4.11.2, 4.27.4] Yes No
-
H25
H25. Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees? [ADA Standards §...
-
L1
L1. Is there a backup source of electrical power for the facility? Yes No
-
H9
H9. Are the drain and hot water pipes for this lavatory insulated or otherwise configured to protect against contact? [ADA Standards § 4.19.4] Yes No
-
f-v
f-v. Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? [ADA Standards §§ 4.11.2,...
-
M8
M8. Is there at least 18 inches between the center of the toilet and the side of the adjacent lavatory? [ADA Standards § 4.16.2; Fig. 28] Yes No
-
H20
H20. Is the flush valve located on the wide side adjacent to the lavatory or is an automatic flush valve provided? [ADA Standards § 4.16.5] Yes No
-
M3
M3. Is the hardware (e.g., lever, pull, etc.) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9] Yes No If No,...
-
J2
J2. If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the...
-
H5
H5. If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides? [ADA Standards §§ 4.1.6(3)(d)(ii), 4.13.8] Yes No NA If...
-
B7
B7. If there is a curb between the access aisle and the accessible route to the building, is there a curb ramp that meets the following requirements: [ADA Standards §...
-
C2‒2
C2‒2. Are the undersides of exterior stairs enclosed or protected with a cane-detectable barrier so that people who are blind or have low vision will not hit their heads on the...
-
D4
D4. On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated? [ADA Standards § 4.13.6, Fig....
-
f-ii
f-ii. Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No
-
f-iii
f-iii. Is there at least a 30-inch by 48-inch clear floor space on the wheelchair lift? [ADA Standards §§ 4.11.2, 4.2.4] Yes No
-
E1-b
E1-b. Is the accessible route free of steps and abrupt level changes over 1/2 inch? Yes No Note: level changes between 1/4 inch and 1/2 inch should be beveled). [ADA...
-
B4
B4. For van-accessible spaces (particularly in a garage or parking structure), is there vertical clearance of at least 98 inches (8 feet - 2 inches) for the vehicle route to the...
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction. EXCEPTION: Where the floor surface is other than asphalt, concrete, or boards, slopes not steeper...
-
Section 9, Accessible Transient Lodging (Preamble, Section-by-Section Analysis)
In new construction, homeless shelters and other social service entities must comply with ADAAG; at least one type of amenity in each common area must be accessible....