Public entities are directed to develop a "transition plan" to "achieve program accessibility" by "setting forth the steps necessary to complete such changes." 28 C.F.R. § 35.150(d)(1);...
Search Results "Transit Stop"
Commonly Searched Documents
-
A. TITLE II OF THE ADA
- Figure 303.2 Vertical Change in Level – Drawing from the U.S. Access Board
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
R304.1 General
Curb ramps and blended transitions shall comply with R304. Advisory R304.1 General....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
II-8.1000 General
In addition, public entities with 50 or more employees are required to -- 1) Develop a grievance procedure; 2) Designate an individual to oversee title II compliance; 3) Develop a transition...
-
R304.5.1.1 Pedestrian Circulation Paths Other Than Shared Use Paths
In pedestrian circulation paths other than shared use paths, the clear width of curb ramp runs, blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
10.1 General
Every station, bus stop, bus stop pad, terminal, building or other transportation facility, shall comply with the applicable provisions of 4.1 through 4.35, sections 5 through 9, and the...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-206.2.19 Pedestrian street crossings
Where walks or sidewalks are provided, a curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with Section 11B-406 shall connect the walks or sidewalks...
-
Requirements to Remember for: Remanufacture or Rebuilt Vehicles
[See subsections ...]
-
§35.150(d)(3)
(3) The plan shall, at a minimum --
-
Thresholds at Doorways [4.13.8]
Thresholds at Doorways [4.13.8] Thresholds complicate wheelchair maneuvering through doors, especially at doors equipped with closers. Negotiating level changes while...
-
§ 35.150(d)(3)
(3) The plan shall, at a minimum—
-
Section 37.153 FTA Waiver Determination
Section 37.153 FTA Waiver Determination If the FTA Administrator grants a waiver for undue financial burden, the waiver will be for a specified period of time and the...
-
Boat Slips: ADA Standard Section 1003.2.1
Where gangways connect to transition plates, landings specified by 405.7 shall not be required. 6....
-
11B-1003.2.1 Boat slips
Another design solution would be to have two 40 foot (12 m) plus continuous gangways joined together at a float, where the float (as the water level falls) will stop dropping at an elevation...
-
§27.71(g)
(g) If an airport operator who receives Federal financial assistance for an existing airport facility has not already done so, the recipient shall submit a transition plan meeting the requirements...
-
1.3 Previous Research
However, now that curb ramps and other flush transitions are used at crosswalks to improve the accessibility of sidewalks for people who cannot negotiate curbs, the curb edge has become...
-
R304.5.1.2 Shared Use Paths
In shared use paths, the width of curb ramps runs and blended transitions shall be equal to the width of the shared use path....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...