Cross slope is the slope or grade of a surface perpendicular to the running slope. The most cross slope allowed on an accessible route is 1:50 (2% or 1.15 degrees)....
Search Results "Track Crossing"
Commonly Searched Documents
-
1. Sloped Surfaces
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
Issue 2: Location relative to the crosswalk
Issue 2: Location relative to the crosswalk An APS that is mounted outside the crosswalk area may provide misleading information about the crossing location....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
Boat Slips: ADA Standard Section 1003.2.1
The cross slope specified in 403.3 and 405.3 for gangways, transition plates, and floating piers that are part of accessible routes shall be measured in the static position. 8....
-
11B-1003.2.1 Boat slips
The cross slope specified in Sections 11B-403.3 and 11B-405.3 for gangways, transition plates, and floating piers that are part of accessible routes shall be measured in the static position...
-
Q12: Full-depth Pavement Patching
If the pavement patching impacts the curb at a pedestrian street crossing where no curb ramp exists, the work affecting the curb falls within the definition of “alteration,” and a curb ramp...
-
Issue 3: Which signal? Speech WALK messages necessary
Pedestrians standing at one crosswalk could mistake the message of the other crosswalk for their indication to begin crossing....
-
M305.2.4 Cross Section (Section-by-Section Analysis)
with non-circular cross sections to have a cross section dimension of 2 inches maximum, and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
-
Issue 4: Wrong pole! …Wrong message!
Since the APS is closer to the departure curb and curb ramp for crossing straight ahead (in line with the photographer’s direction of travel), a pedestrian hearing the sound from that APS...
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
In such cases, an overhead track lift, either permanently mounted or free-standing, may provide access to the equipment....
-
Tactile arrow
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
-
11B-406.5.1 Location
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
11B-406.5.1 Location
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
11B-406.5.1 Location
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
Accessible Slopes
For the cross slope of an accessible route the maximum slope allowed is 1:48....
-
Issue 13: Stub poles
which the APS volume had to be set to be quite loud in order to be heard at the crosswalk and where using the tactile arrow and vibrotactile WALK indication could result in a hazardous crossing...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where fixed overhead patient...
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base...
-
M301.4 Lift Compatibility
M301.4 Lift Compatibility Subcommittee Recommendation: (Also agreed to by the full committee.) An overhead lift (and possibly a gurney-based transfer) may be used in lieu of...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where diagnostic equipment meets the requirements of M303 and...
-
Significant alternatives which minimize any significant economic impacts on small entities
Maximum cross slope of 2 percent required on pedestrian access routes, including within pedestrian street crossings with yield or stop control....
-
Step 2: Identify the Presence of Limiting Factors
Does the combined trail running slope (grade) and cross slope exceed 1:2.5 (40 percent) for a continuous distance of 20 feet (6 meters) or more?...
- Where to Measure Along the Route