Section 407.4.9: covers the current ADA Standards for the elevator emergency communication systems.
Search Results "Raised Curb"
Commonly Searched Documents
-
Emergency Communication: ADA Standard Section 407.4.9
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. In transfer type shower compartments, thresholds ½ inch...
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
703.2.4 Character Proportions
703.2.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the...
-
703.2.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I". [ECTCR...
-
703.2.2 Case
703.2.2 Case. Characters shall be uppercase.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
703.2.2 Case
Characters shall be uppercase.
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
703.2.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I".
-
703.2.2 Case
Characters shall be uppercase.
-
11B-703.2.2 Case
11B-703.2.2 Case. Characters shall be uppercase.
-
11B-703.2.4 Character proportions
11B-703.2.4 Character proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of...
-
11B-703.2.2 Case
Characters shall be uppercase.
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
Can ramps be portable or provided after construction as an adaptation?
All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
-
11 [§ 4.7.6]
11 [§ 4.7.6] A built-up curb ramp typically consists of asphalt or concrete that is poured and shaped into a ramp that runs at a 90-degree angle away from an intact curb down to the roadway...
-
General (R304.1) (Section-by-Section Analysis)
General (R304.1) (Section-by-Section Analysis) Curb ramps are ramps that are cut through or built up to the curb (see R105.5)....
-
Turning Space: ADA Standard Section 808.2
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
8 [§§ 4.3.3; 4.3.7]
8 [§§ 4.3.3; 4.3.7] Curb ramps should have at least 36 inches of clear space at the “top” of the ramp, which can be seen in the illustration to the right [below]....
-
11B-808.2 Turning space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with Section 11B-304....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....