The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
Search Results "Privacy Latch"
Commonly Searched Documents
-
1132A.8.1 Lever-type hardware
-
707 Automatic Teller Machines and Fare Machines
Requirements address clear floor or ground space (707.2), operable parts (707.3), privacy (707.4), speech output (707.5), input (707.6), display screens (707.7), and braille instructions...
-
Do all state and local buildings need to be accessible (comply with the ADA Standards for Accessible Design?)
built in 1968 that doesn’t have an elevator, staff on the second floor could meet with citizens on the first floor if meeting space is comparable to that on the second floor in terms of privacy...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
enter his or her own personal identification number or any other personal information necessary to process the transaction in a manner that provides the opportunity for the same degree of privacy...
-
4.3.9 Doorway Design
The lack of differences between the findings for the passage task on the pull sides of Doors 1, 800 mm (31.5 in.) latch clearance, and Door 2, 406 mm (16 in.) latch clearance, demonstrate...
-
Kitchen Appliances
In the addition, the Board has added exceptions for appliance doors and door latching devices in section 804.6.2. Comment....
-
804.6.2 Operable Parts
Appliance doors and door latching devices shall not be required to comply with 309.4. 2....
-
804.6.2 Operable Parts
Appliance doors and door latching devices shall not be required to comply with 309.4. 2....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Doors in a Series
The Model Barrier Code for Residential Swimming Pools, Spas, and Hot Tubs (ANSI/NSPI−8 1996) permits latch releases for chain link or picket fence gates to be above 54 inches....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
4.13.10* Door Closers
closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (75 mm) from the latch...
-
4.13.10* DOOR CLOSERS
closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (75 mm) from the latch...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Sliding Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular to Doorway Parallel to Doorway (beyond stop/latch...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
DOORS Minimum Maneuvering Clearance Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch...
-
Signage
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....