2.4. “EXIT RAMP UP”
Search Results "Means of Egress"
Commonly Searched Documents
-
1013.4, Item 2.4
-
1013.4, Item 2.3
2.3. “EXIT STAIR UP”
-
1013.4, Item 5
5. Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” Raised character and Braille...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles,...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load...
-
1018.3 Aisles in Groups B and M
1018.3 Aisles in Groups B and M. In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less...
-
1009.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and a central control point location approved by the fire department. Where the central...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location and a central control point...
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles, from the...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1009.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space. Doors in a series shall swing either in the same direction...
-
207.2 Platform Lifts
Supplement) or section 1007.5 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to serve as a part of an accessible means...
-
General
The 1991 Standards at sections 4.1.3(9); 4.1.6(1)(g); and 4.3.10 establish scoping and technical requirements for accessible means of egress....
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
In addition, the IBC requires a tactile “EXIT” sign adjacent to the door to an egress stairway, an exit passageway, and the exit discharge (§1011.3, §1003.2.10.3 – 2000 addresses doors to...
-
Standby Power for Platform Lifts
The 2010 Standards at section 207.2 require standby power to be provided for platform lifts that are permitted to serve as part of an accessible means of egress by the IBC....
-
General: ADA Standard Section 210.1
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
Cognitive Disabilities
All standard building egress systems require a person to be able to process and understand information in order to safely evacuate a building....